D1014D SIL 2 Repeater Power Supply Safe Isolator

Ürün Özellikleri

  • 🔹 SIL2 / SC3 Uyumlu
  • 🔹 Zone 0 (Zone 20), Division 1 Giriş — Zone 2, Division 2 Kurulum
  • 🔹 Yüksek Yoğunluk: Her Ünitede İki Kanal
  • 🔹 4–20 mA Giriş / Çıkış Sinyali
  • 🔹 HART® Uyumlu Geniş Bant İletişim
  • 🔹 Giriş ve Çıkışlarda Kısa Devre Koruması
  • 🔹 Üçlü İzolasyon: Giriş / Çıkış / Güç
  • 🔹 EMC Uyumluluğu: EN61000-6-2, EN61000-6-4, EN61326-1
  • 🔹 DIP Switch ile Sahada Programlanabilir
  • 🔹 250 Vrms Maksimum Gerilim Toleransı
🟡 PHASE-OUT
Yedek Parça Desteği: 01.01.2027’ye Kadar

Description

TypeDescription
Supply Voltage12-24 Vdc nom (10 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp.
Supply Current Consumption110 mA with 20 mA output typical
Supply Power Dissipation1.8 W with 24 V supply voltage and 20 mA output typical
Supply Max. power consumptionat 30 V supply voltage and short circuit condition, 3.4 W
Input Type4 to 20 mA (2 wire Tx current limited at ≈ 25 mA).
Input Transmitter line voltage≥ 15.0 V at 20 mA with max. 20 mVrms ripple on 0.5 to 2.5 KHz frequency band.
Output Type4 to 20 mA, on max. 600 Ω load in source mode; V min. 5 V at 0 Ω load V max. 30 V in sink mode, current limited at ≈ 25 mA or 1 to 5 V on internal 250 Ω shunt (or 2 to 10 V on internal 500 Ω shunt on request).
Output Response time20 ms (10 to 90 % step change).
Output Output ripple≤ 20 mVrms on 250 Ω communication load on 0.5 to 2.5 KHz band.
Output Frequency response0.5 to 2.5 KHz bidirectional within 3 dB (HART® protocol).
Performance TypeRef. Conditions 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Performance Calibration accuracy≤ ± 0.1 % of full scale.
Performance Linearity error≤ ± 0.1 % of full scale.
Performance Supply voltage influence≤ ± 0.05 % of full scale for a min to max supply change.
Performance Load influence≤ ± 0.05 % of full scale for a 0 to 100 % load resistance change.
Performance Temperature influence≤ ± 0.01 % on zero and span for a 1 °C change.
Isolation Test VoltageI.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V.
Environmental conditions Operatingtemperature limits -20 to + 60 °C, relative humidity max 95 %.
Environmental conditions Storagetemperature limits – 45 to + 80 °C.
Safety description Safety parametersUo/Voc = 25.2 V, Io/Isc = 93 mA, Po/Po = 585 mW at terminals 14-15, 10-11. Um = 250 Vrms, -20 °C ≤ Ta ≤ 60 °C.
Mounting TypeEN/IEC60715 TH 35 DIN-Rail.
Mounting Weightabout 170 g
Mounting Connectionby polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm2.
Mounting LocationSafe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation.
Mounting Protection classIP 20.
Mounting DimensionsWidth 22.5 mm, Depth 99 mm, Height 114.5 mm.

Additional information

GMI-Applications

Analog Input

SIL Seviyesi

SIL 2