| Supply Voltage | 24 Vdc nom (18 to 30 Vdc), reverse polarity protected |
| Current Consumption | 50 mA @ 24 Vdc with 20 mA out, typical. |
| Power Dissipation | 0.8 W @ 24 Vdc with 20 mA out, typical. |
| Input Type | 4 to 20 mA (2 wires Tx current limited ≈ 25 mA), reading range 0 to 24 mA. |
| Transmitter Line Voltage | 16.5 V minimum @ 20 mA. |
| Output Type | 4 to 20 mA, on max. 600 Ω load in source mode; V min. 2 V @ 0 Ω load V max. 30 V in sink mode (max. load resistance 600 Ω), current limited @ ≈ 25 mA. |
| Response Time | 5 ms. |
| Performance (Ref. Conditions) | 24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature. |
| Calibration Accuracy | ≤ ± 20 μA. |
| Linearity Accuracy | ≤ ± 10 μA. |
| Temperature Influence | ≤ ± 2 μA/°C. |
| Isolation Test Voltage | I.S. In/Out 2.5 kV; I.S. In/Supply 2.5 kV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V. |
| Operating Temperature | temperature limits –40 to +70 °C. |
| Storage Temperature | temperature limits –45 to +80 °C. |
| Safety Description | Associated apparatus and non-sparking electrical equipment. |
| Safety Parameters | Uo = 26.8 V, Io = 92 mA, Po = 614 mW at terminals 7-8. Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 8-11. Ui = 30 V, Ii = 128 mA, Ci = 0 nF, Li = 0 nH at terminals 8-11. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C. |
| Mounting Type | DIN-Rail 35 mm, with or without Power Bus or on custom Term. Board. |
| Weight | about 130 g. |
| Connection | by polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG). |
| Dimensions | Width 12.5 mm, Depth 123 mm, Height 120 mm. |