Arya Automation & Otomasyon Çözümleri
📅 --/--/----
USD USD: TRY
EUR EUR: TRY
GBP GBP: TRY

PSM1250 Industrial SIL3 Power Supply 24VDC Module

PSM1250 Industrial SIL3 Power Supply 24VDC Module

Key Features

  • 🔹 SIL 3 For NE Load With Single Or Redundant PSM1250 Modules
  • 🔹 SIL 1 / SIL 2 For ND Load In Single Or Redundant Configuration
  • 🔹 Nominal 110–240 Vac (±10%), 48–62 Hz Dual AC Input
  • 🔹 Hot-Swappable Module Design For Zone 2 / Div. 2 Locations
  • 🔹 24 Vdc / 50 A Highly Regulated Output With Load Sharing
  • 🔹 Power Factor Correction & 3-Stage Redundant Protection
  • 🔹 TÜV Certified – ATEX, UL, IECEx, C-UL, Maritime Tested
  • 🔹 Mosfet Active Ideal Diode For Reduced Power Dissipation
  • 🔹 89% Efficiency @230 Vac, Fan Speed Controlled By Ambient
  • 🔹 Modbus RTU RS-485 Diagnostic Output (With PSO1250)
  • 🔹 Rugged 4U Rack Mount – Available For 19″, 9″, Or 7″ Systems
🟢 Active
Discover PSX1200 – Product Lifecycle Policy

Description

Supply
AC Input Voltage Nominal 110 to 240 Vac (±10%), with frequency range 48 to 62 Hz.
Power Factor Correction 0.98 typ.@230Vac, 0.995 typ.@115Vac (full load).
Efficiency @24Vdc Out (Full Load) Better than 89% @ 230 Vac, 86% @ 115 Vac.
Max. Internal Power Dissipation 150 W @ 230 Vac, 195 W @ 115 Vac.
AC Input Current 14.2A @100Vac, 12.2A @115Vac, 6.1A @230Vac.
Inrush Current 37 A peak @ 264 Vac, 32 A peak @ 230 Vac, 16 A peak @ 115 Vac.
AC Input Connection Screw terminal blocks suitable for 4mm² wires on back panel PCB.
Isolation
Input to Output 2500 Vrms (routine test).
Input to Earth-Ground 1500 Vrms (routine test).
Earth-Ground to Output 500 Vrms (routine test).
Output or Earth-Ground to Fault Contact 500 Vrms (routine test).
Output
Voltage 24 Vdc (adjustable 21–28 Vdc).
Regulation 0.4% for 100% load change.
Stability 0.01% for 20% line voltage change.
Ripple ≤ 250 mVpp.
Output Current 50 A nominal @24Vdc. Supports redundancy with ±5% load sharing.
Output Power Up to 1300 W nominal @28Vdc.
Output Rise Time 2.5 s.
Dynamic Response 2 ms for 0–100% load change (±1.5% overshoot).
DC Connection M6 screw terminals on copper bars for lugs (≥6.5 mm hole) and 16mm² wire.
Hold-up Time 20 ms (AC input, full load).
Over Voltage Protection Output limited to 30 Vdc with two crowbars.
Power Good Signaling
Output Good 19.5 V ≤ Vout ≤ 29.5 V.
Indication LCD screen on PSO1250 and Modbus RTU RS-485 protocol.
Signaling Voltage free SPST relay (normally energized).
Contact Rating 2 A 50 Vac 100 VA, 2 A 24 Vdc 48 W (resistive load).
Connection Screw terminal blocks suitable for 1.5mm² wires.
Environmental Conditions
Operating Temperature -40 to +70°C, de-rated 65–70% load above 50°C.
Relative Humidity 95% up to 55°C.
Storage Temperature -45 to +85 °C.
Max Altitude 2000 m a.s.l.
Mechanical
Mounting For 7”, 9” or 19” rack units (wall or frontal mounting in cabinet).
Weight 2.2 Kg.
Location Safe Area / Zone 2 / Class I, Div. 2.
Protection Class IP 20, Open Type.
Dimensions Width 60 mm, Depth 345 mm, Height 172 mm.

Additional information

GMI-Power-Supplies

Power Supply System

GMI-Status

Active

Certifications

Type Description Area Number Issued by Issue Date
ATEX DEKRA ATEX PSS1250, PSW1250, PSW1230 Series English Certificate ( EN ) Europe BVS 15 ATEX E 006 X DEKRA 2022-08-01
Ex PSx1200 CCC certificate for China ( EN ) China 2020322303000822 NEPSI 2023-04-30
FSM TUV IT 22 SIL 0093 Functional Safety Certificate ( EN ) International TUV IT 22 SIL 0093 TUV_SUD 2022-07-25
IECEx DEKRA IECEx PSS1250, PSW1250, PSW1230 Series Certificate ( EN ) International IECEx BVS 15.0006X DEKRA 2022-09-08
WhatsApp Mail