Arya Automation & Otomasyon Çözümleri
📅 --/--/----
USD USD: TRY
EUR EUR: TRY
GBP GBP: TRY

D1063S Gauge Bridge Isolating Repeater Isolator

D1063S Gauge Bridge Isolating Repeater Isolator

Ürün Özellikleri

  • 🔹 Zone 0 (Zone 20), Division 1’den Giriş, Zone 2, Division 2’ye Kurulum
  • 🔹 Strain Gauge Köprü Tipi Şeffaf Tekrarlayıcı
  • 🔹 4×350 Ω, 6×450 Ω veya 12×1000 Ω Yük Hücresi ile Uyumlu
  • 🔹 Saha Kablo Kopma Hatası Algılama
  • 🔹 Yüksek Doğruluk
  • 🔹 Giriş/Çıkış/Güç Arasında Üçlü İzolasyon
  • 🔹 EN61000-6-2, EN61000-6-4 ile EMC Uyumluluğu
  • 🔹 DIP Switch ile Sahada Programlanabilirlik
  • 🔹 250 Vrms (Um) Maksimum İzin Verilen Gerilim
🟢 Phase Out
Discover D1000

Dimensions

Connections

Description

Type Description
Supply Voltage 24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp.
Current Consumption 80 mA with four 350 Ω load cells connected, typical.
Power Dissipation 1.7 W with 24 V supply and four 350 Ω load cells connected typical.
Max. Power Consumption At 30 V supply voltage and short circuit input, 2.8 W.
Input Type Up to four 350 Ω, six 450 Ω, or twelve 1000 Ω load cells in parallel.
Bridge Supply Voltage 4.5 V nominal.
Bridge Output Signal ≤ 4 mV/V.
Input Range ± 18 mV nominal span, ± 22 mV overrange.
Line Resistance Compensation ≤ 10 Ω.
Burnout Type LED indication for field wire breakage.
Output Type ± 20 mV nominal span, ± 24 mV overrange (5 V ref); ± 40 mV nominal span, ± 48 mV overrange (10 V ref).
Output Impedance 350 Ω typical.
Host Reference Voltage ≤ 10 V typical, ≤ 11 V maximum.
Internal Reference Voltage 10 V typical, DIP switch settable.
Internal Impedance 350 Ω typical, DIP switch settable.
Transfer Characteristic Linear based on mV input.
Response Time ≤ 100 ms (10 to 90 % step change).
Performance Type Ref. conditions 24 V supply, 23 ± 1 °C ambient temperature.
Calibration Accuracy ≤ ± 0.003 % of full scale of input range.
Linearity Accuracy ≤ ± 0.002 % of full scale of input range.
Supply Voltage Influence ≤ ± 0.002 % of full scale for a min to max supply change.
Temperature Influence ≤ ± 0.002 % of full scale of input range for a 1 °C change.
Isolation Test Voltage I.S. In/Out 1.5 kV; I.S. In/Supply 1.5 kV; Out/Supply 500 V.
Operating Conditions Temperature limits –20 to +60 °C, RH max 90 % non-condensing up to 35 °C.
Storage Conditions Temperature limits –45 to +80 °C.
Safety Parameters Uo = 17.3 V, Io = 199.6 mA, Po = 864 mW at terminals 9–14; Ui = 30 V, Ci = 0 nF, Li = 0 nH; Um = 250 Vrms, –20 °C ≤ Ta ≤ 60 °C.
Mounting Type EN/IEC60715 TH 35 DIN-Rail.
Weight About 165 g.
Connection By polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm².
Location Safe Area/Non Hazardous or Zone 2, Class I, Div 2, Group IIC T4 installations.
Protection Class IP 20.
Dimensions Width 22.5 mm, Depth 99 mm, Height 114.5 mm.

Additional information

GMI-Applications

Load Cell Input

WhatsApp Mail