Arya Automation & Otomasyon Çözümleri
📅 --/--/----
USD USD: TRY
EUR EUR: TRY
GBP GBP: TRY

D1043Q SIL 3 – SIL 2 Digital Output Safe Isolator

D1043Q SIL 3 – SIL 2 Digital Output Safe Isolator

Ürün Özellikleri

  • 🔹 SIL2 / SIL3 Uyumlu
  • 🔹 Zone 0 (Zone 20), Division 1 Giriş – Zone 2, Division 2 Kurulum
  • 🔹 Yüksek Yoğunluk: Ünite Başına 4 Kanal
  • 🔹 Gerilim Girişi, Kontak, Lojik Seviye – Ortak Pozitif veya Ortak Negatif, Loop veya Bus Beslemeli
  • 🔹 Esnek Modüler Çoklu Çıkış Desteği
  • 🔹 Çıkış Kısa Devreye Karşı Korumalı ve Akım Sınırlamalı
  • 🔹 Üç Port İzolasyonu: Giriş / Çıkış / Besleme
  • 🔹 EMC Uyumluluğu: EN61000-6-2, EN61000-6-4
  • 🔹 Maks. 250 Vrms (Um) İzin Verilen Gerilim
🟡 PHASE-OUT
Yedek Parça Desteği: 01.01.2027’ye Kadar

Data Sheet

Data Sheet
  • Datasheet of D1010 (EN)
  • D1000 Series Common Specifications and Dimensional Drawing (EN)
Instruction Manual
  • Instruction Manual D1010 (EN)
  • Instruction Manual D1000 Series (EN | RU)
  • Ex Safety Instruction Manual for D1000 Series (EN | IT)
  • Ex Safety Instruction Manual for D1000 Series (IT)
  • INMETRO Safety Instruction Manual for D1000 Series (PT)
  • UL Control Drawing D1010 (EN)

Dimensions

Approvals

Type Description Area Number Issued By Issue Date
ATEX DEKRA ATEX D1000 Series English Certificate (EN) Europe DMT 01 ATEX E 042 X DEKRA 2022-04-25
ATEX IMQ Zone 2 Applications D1000 Series Certificate (EN) Europe IMQ 09 ATEX 013 X IMQ 2022-05-03
EMC D1000 EAC EMC Declaration of Conformity (RU) Eurasian Community ЕАЭС N RU Д-IT.НХ37.В.06311/20 EUROCERT 2020-08-13
Ex EAC Ex Certificate for D1000 Series (RU) Eurasian Community ЕАЭС RU С-IT.НА67.В.00113/20 TECHNOPROGRESS 2020-09-04
Ex UL-cUL D1010, D1020 Divisions and Zones (EN) North America 20130115-E222308C UL 2013-01-15
Ex FM No.3024643-3029921C Certificate (EN) North America 3024643-3029921C FM 2005-12-16
Ex INMETRO Certificate DNV 13.0108 X for D1000 Series (EN) Brazil DNV 13.0108 X DNV 2022-12-10
FSM TUV IT 22 SIL 0093 Functional Safety Certificate (EN) International TUV IT 22 SIL 0093 TUV_SUD 2022-07-25
IECEx IMQ IECEx Zone 2 Applications D1000 Series Certificate (EN) International IECEx IMQ 13.0011X IMQ 2022-05-03
IECEx DEKRA IECEx for D1000 Series (EN) International IECEx BVS 07.0027X DEKRA 2022-05-30
Maritime KR Maritime Certificate D1000 Series (EN) International MIL20769-EL001 KR 2022-07-04
Maritime DNV Maritime Certificate TAA00002BM for D1000 Series (EN) International TAA00002BM DNV-GL 2024-04-05
Metrological Metrological Certificate Russia for D1000 Series (RU) Russia 64283-11 ROSSTANDART 2021-03-10
SIL TUV C-IS-236198-03 SIL Certificate Summary (EN) International C-IS-236198-03 TUV_SUD 2022-10-14

Connections

Description

 

Type Description
Supply Voltage 24 Vdc nom (21.5 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp.
Supply Current Consumption 130 mA with four channels energized at nominal load, 150 mA with short circuit output
Supply Power Dissipation 2.3 W with 24 V supply voltage and four channels energized at nominal load.
Supply Max. power consumption at 30 V supply voltage and short circuit output, 4.0 W
Input Type switch contact, logic level common positive or common negative or loop powered.
Input Trip voltage levels OFF status ≤ 1.0 V, ON status ≥ 6.0 V (maximum 30 V).
Input Current Consumption 3 Ma @24V (≈ 10 KΩ input impedance).
Output Type 22 mA at 9.8 V per channel (20.5 V no load, 484 Ω series resistance).
Output Short circuit current ≥ 24 mA per channel (26 mA typical)
Output Response time 20 ms (power up in 600 ms typical in loop powered mode).
Isolation Test Voltage I.S. Out/In 1.5 KV; I.S. Out/Supply 1.5 KV; In/Supply 500 V.
Environmental conditions Operating temperature limits -20 to + 60 °C, relative humidity max 90 % non condensing, up to 35 °C.
Environmental conditions Storage temperature limits -45 to + 80 °C.
Safety description Safety parameters Uo/Voc = 23.6 V, Io/Isc = 49.6 mA, Po/Po = 292 mW at terminals 13-14,15-16,9-10,11-12.
Mounting Type EN/IEC60715 TH 35 DIN-Rail.
Mounting Weight about 130 g.
Mounting Connection by polarized plug-in disconnect screw terminal blocks to accomodate terminations up to 2.5 mm2.
Mounting Location Safe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation.
Mounting Protection class IP 20.
Mounting Dimensions Width 22.5 mm, Depth 99 mm, Height 114.5 mm.

Additional information

GMI-Applications

Digital Output

SIL Seviyesi

SIL 2

WhatsApp Mail