USD USD: TRY
EUR EUR: TRY
GBP GBP: TRY

D1010S-046 SIL 2 Repeater Power Supply Safe Isolator

Ürün Özellikleri

  • 🔹 SIL2 / SC3 Uyumlu
  • 🔹 Zone 0 (Zone 20) Giriş, Zone 2 Kurulum
  • 🔹 Yüksek Yoğunluk: Her Ünitede İki Kanal
  • 🔹 4–20 mA veya 0–20 mA Giriş / Çıkış Sinyali
  • 🔹 HART® Uyumlu Geniş Bant Akıllı İletişim
  • 🔹 Kısa Devre Korumalı Giriş ve Çıkış
  • 🔹 Yüksek Doğruluk
  • 🔹 Üç Port İzolasyon: Giriş / Çıkış / Besleme
  • 🔹 EMC Uyumluluğu: EN61000-6-2, EN61000-6-4, EN61326-1
  • 🔹 DIP Switch ile Sahada Programlanabilir
  • 🔹 250 Vrms Maksimum Gerilim Toleransı
🟡 PHASE-OUT
Yedek Parça Desteği: 01.01.2027’ye Kadar

Description

TypeDescription
Supply Type24 Vdc nom (20 to 30 Vdc) reverse polarity protected, ripple within voltage limits ≤ 5 Vpp.
Supply Current Consumption60 mA @24V with 20 mA output typical.
Supply Power Dissipation1.9 W with 24 V supply voltage and 20 mA output typical.
Supply Max. power consumption2.0 W at 30 V supply voltage and short circuit condition
Input Type0/4 to 20 mA (separately powered input, voltage drop ≤ 0.9 V) or 4 to 20 mA (2 wire Tx current limited at ≈ 25 mA).
Input Transmitter line voltage≥ 15.0 V at 20 mA with max. 20 mVrms ripple on 0.5 to 40 KHz frequency band.
Output Type0/4 to 20 mA, on max. 600 Ω load in source mode; V min. 5 V at 0 Ω load V max. 30 V in sink mode, current limited at ≈ 23 mA or 0/1 to 5 V on internal 250 Ω shunt (or 0/2 to 10 V on internal 500 Ω shunt on request).
Output Response time50 ms (10 to 90 % step change).
Output Output ripple≤ 20 mVrms on 250 Ω communication load on 0.5 to 40 KHz band.
Output Frequency response0.5 to 40 KHz bidirectional within 3 dB (HART® and higher frequency protocols).
Performance Ref. Conditions24 V supply, 250 Ω load, 23 ± 1 °C ambient temperature.
Performance Calibration accuracy≤ ± 0.1 % of full scale.
Performance Linearity error≤ ± 0.05 % of full scale.
Performance Supply voltage influence≤ ± 0.05 % of full scale for a min to max supply change.
Performance Load influence≤ ± 0.05 % of full scale for a 0 to 100 % load resistance change.
Performance Temperature influence≤ ± 0.01 % on zero and span for a 1 °C change.
Isolation Test VoltageI.S. In/Out 1.5 KV; I.S. In/Supply 1.5 KV; I.S. In/I.S. In 500 V; Out/Supply 500 V; Out/Out 500 V.
Safety description EquipmentAssociated apparatus and non-sparking electrical equipment
Safety description Safety parametersUo/Voc = 26.3 V, Io/Isc = 91 mA, Po/Po = 597 mW at terminals 14-15, 10-11. Uo/Voc = 1.1 V, Io/Isc = 38 mA, Po/Po = 11 mW at terminals 15-16, 11-12. Ui/Vmax = 30 V, Ii/Imax = 104 mA, Ci = 1.05 nF, Li = 0 nH at terminals 15-16, 11-12. Um = 250 Vrms, -20 °C ≤ Ta ≤ 60 °C.
Environmental conditions Operating temperaturetemperature limits -20 to + 60 °C, relative humidity max 95 %.
Environmental conditions Storage temperaturetemperature limits -45 to + 80 °C.
Mounting TypeEN/IEC60715 TH 35 DIN-Rail.
Mounting Weight125 g
Mounting Connectionby polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm2.
Mounting LocationSafe Area/Non Hazardous Locations or Zone 2, Group IIC T4, Class I, Division 2, Groups A, B, C, D Temperature Code T4 and Class I, Zone 2, Group IIC, IIB, IIA T4 installation.
Mounting Protection classIP 20.
Mounting DimensionsWidth 22.5 mm, Depth 99 mm, Height 114.5 mm.

 

Additional information

GMI-Applications

Analog Input

SIL Seviyesi

SIL 2

GMI-Input-Range

24 Vdc

GMI-Temperature

-20…+60 °C

GMI-Status

Phase Out