D5254S SIL2 4-Wire Transmitter Safe Isolator

Key Features

  • 🔹 SIL 3 / SC 3 Certified
  • 🔹 Input From Zone 0 / Division 1
  • 🔹 Installation In Zone 2 / Division 2
  • 🔹 2 Fully Independent Channels
  • 🔹 4-20 mA Source-Sink Output
  • 🔹 HART® Compatible
  • 🔹 High Accuracy
  • 🔹 Three-Port Isolation (Input/Output/Supply)
  • 🔹 High Density – Two Channels Per Unit
🟢 Active
Discover D5000 – Product Lifecycle Policy

Description

Supply
Type24 Vdc nom (21.5 to 30 Vdc), reverse polarity protected.
Current Consumption110 mA @ 24 Vdc with 20 mA input/output and alarm relays energized, typical.
Power Dissipation2.3 W @ 24 Vdc with 20 mA input/output and alarm relays energized, typical.
Input
Type0/4 to 20 mA (separately powered input, voltage drop ≤ 0.5 V) or 4 to 20 mA (2 wires Tx current limited ≈ 25 mA), or voltage input ±12 V.
Integration Time100 ms.
Input Range0 / +25 mA for current, ± 12 V for voltage.
Transmitter Line Voltage15.5 V typical, 15.0 V minimum, @ 20 mA.
Acknowledgement Input
TypeLogic level reverse polarity protected.
Voltage Range0 V ≤ OFF ≤ 5 V, 18 V ≤ ON ≤ 30 V.
Current Consumption10 mA @ 24 Vdc, typical.
Output
TypeFully customizable 0/4 to 20 mA, on max. 300 Ω load source mode, current limited @ 25 mA.
Transfer CharacteristicLinear, direct or reverse, square root.
Response Time≤ 100 ms (10 to 90% step change).
Alarm
Trip Point RangeWithin rated limits of input sensor.
OutputTwo voltage free SPDT relay contacts.
Contact Rating4 A 250 Vac 1000 VA, 4 A 250 Vdc 120 W (resistive load).
DC and AC Load Breaking CapacityRefer to Instruction Manual.
Modbus Interface
TypeModbus RTU RS-485 up to 115.2 kbps for monitor/configuration/control.
Isolation
Test VoltageI.S. In/Other 1.5 kV; Alarms/Other 1.5 kV; Alarm/Alarm 1.5 kV; Out/Supply 500 V; Out/Ack 500 V; Ack/Supply 500 V.
Environmental Conditions
Operating TemperatureTemperature limits –40 to +70 °C.
Storage TemperatureTemperature limits –45 to +80 °C.
Safety Description
EquipmentAssociated apparatus and non-sparking electrical equipment.
Safety ParametersUo = 26 V, Io = 91 mA, Po = 588 mW at terminals 13-14
Uo = 1.1 V, Io = 56 mA, Po = 16 mW at terminals 14-16
Uo = 1.1 V, Io = 0.012 mA, Po = 0.004 mW at terminals 15-16
Ui = 30 V at terminals 14-16 or 15-16, Ii = 128 mA at terminals 14-16, Ci = 2.1 nF, Li = 0 nH at terminals 13-14-15-16. Um = 250 Vrms or Vdc, -40 °C ≤ Ta ≤ 70 °C.
Mounting
TypeDIN-Rail 35 mm, with or without Power Bus or on custom Term. Board.
WeightAbout 120 g.
ConnectionBy polarized plug-in disconnect screw terminal blocks to accommodate terminations up to 2.5 mm² (13 AWG).
DimensionsWidth 22.5 mm, Depth 123 mm, Height 120 mm.

Additional information

GMI-Applications

Analog Input

GMI-Status

Active

GMI-Series

D5000

SIL Seviyesi

SIL 2

GMI-Input-Range

4-20 mA

Max Load Voltage

24 Vdc

GMI-Temperature

-40…+70 °C